Resolving Problems 10-11
Troubleshooting
Chapter 10
Real-Time Report Problems
Problem Probable Cause Action
For non-EAS
installations:
Agent Reports are not
functioning properly.
Login ID option is not
validated.
Validate Login ID at the
DEFINITY system by doing
the following:
If the System Customer
Option Field, “bcms
login IDs,” is set to “y,”
the Feature-related Sys-
tem Parameters Field,
“Validate loginIDs,”
must also be set to “y.”
If “bcms loginIDs” is set
to “n,” call Lucent.
Real-time reports are
not changing.
Lost connection to the
DEFINITY system.
Check connection on status
bar. Try to reconnect to the
DEFINITY system if the
connection is not active and
if the DEFINITY system is
still operational.
Reports and/or
downloads do not
appear to be
functioning.
Lack of proper user
permission
Make sure the login ID for
the DEFINITY system has
the following permissions:
Display Admin and Maint
Data and System
Measurements.
Improper
username/password
Make sure you are using the
correct username/
password combination.
Try manual login on SAT.