Configuring Circuits
5-7
Parameter: Connection Mode
Default: Collision Master
Options: No Dial | Collision Master | Collision Slave
Function: Determines the role of a router when two routers try to establish a demand
circuit with each other. Both routers in a demand configuration can
initiate a call. This parameter determines which router places the call first,
to prevent both routers from placing the call at the same time.
Instructions: To avoid continual collisions, configure one router as Collision Master
and the other as Collision Slave. To ensure that a router receives calls, but
never initiates calls, enter No Dial. Calls are then made only in one
direction.
If this circuit is part of an unnumbered demand circuit group, the router
automatically sets this parameter to No Dial because a circuit in a demand
circuit group cannot initiate a call.a
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.28
Parameter: Auto Demand Termination
Default: Disabled
Options: Enabled | Disabled
Function: For applications where there are two paths to the same destination, this
parameter allows the router to automatically terminate a failed demand
circuit and send the data over an alternate path to the destination. Note
that the router does not terminate the circuit until it reaches the maximum
connection attempts, which you specify in the Retry Max parameter.
Enable this parameter when the router continues to advertise a static route
over a demand circuit, but the router cannot establish a connection over
that circuit. The router terminates the demand circuit, which notifies the
routing protocol that the static routes associated with this circuit are no
longer active. The router then uses the alternate path.
Instructions: Select Enable if you have an alternate path to a remote destination and
you want to ensure that if the demand circuit fails, the router terminates
the circuit and sends data over the alternate path to the destination.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.29