Caller Resolution Table
7-5
Caller Resolution Table Parameters
Parameter: Local Circuit
Default: None
Options: Available circuit name
Function: Identifies a previously configured demand, primary, or bandwidth-on-
demand circuit that is associated with a specific CHAP name or PAP ID.
The router brings up the circuit listed in this parameter when the circuit’s
associated CHAP name or PAP ID is part of the incoming call.
If you enter a value for this parameter, you cannot enter a value for the
Local Group parameter.
Instructions: By selecting a circuit from the Local Circuit List window, Site Manager
automatically fills in this parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.3.1.3
Parameter: Caller Name
Default: None
Options: Any text string; maximum 20 characters
Function: This name is part of the incoming call and it informs the local router of
the remote router’s identity.
Instructions: Enter a text string no longer than 20 characters that identifies a remote
router. If you configure CHAP as the authentication protocol, you must
enter a CHAP name for this parameter. If you configure PAP as the
authentication protocol, you must enter a PAP ID for this parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.3.1.2