Configuring Dial Services
5-22
Parameter: Number of Circuits
Default: None
Options: Maximum number of lines in the line pool
Function: Indicates how many unnumbered circuits are in the demand circuit group
from the selected pool.
Instructions: Enter a number that is less than or equal to the number of lines in the
demand pool associated with this circuit group.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.12.1.4
Configuring the Caller Resolution Information
Once you fill in the demand pool ID and number of circuits, Site Manager
displays the Caller Resolution Info window (Figure 5-12). This window enables
you to enter the CHAP Name or PAP ID of the remote routers that this circuit
group supports.
Site Manager prompts you for this information here because demand circuit
groups cannot initiate calls. By displaying this window, Site Manager ensures that
you make an entry for the remote router in the caller resolution table so that the
local router, configured with the demand circuit group, accepts incoming calls.
Figure 5-12. Caller Resolution Info Window