Configuring Circuits
5-57
Parameter: Maximum Links
Default: 4
Range: 1 to 4
Function: Specifies the maximum number of links (both leased and dial-up lines)
allowed in the multilink bundle for this circuit at any one time.
Instructions: Enter the maximum number of links that you want in the bundle.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.2.1.58
Parameter: BOD Recovery Threshold
Default: 20 percent
Range: 10 to 100 percent
Function: Specifies a percentage of the maximum amount of data that the router
transmits and receives. The actual flow of data traffic must fall below this
percentage for the router to return to the primary line exclusively.
Instructions: Enter a percentage that is less than one half the value of the BOD Full
Threshold parameter. This prevents the router from constantly activating,
then deactivating, the secondary line.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.65
Parameter: BOD Periods to Recover
Default: 10
Range: 1 to 100
Function: Specifies the number of consecutive times the router checks the primary
line and determines that data traffic is below the configured congestion
threshold, thereby concluding that the line is no longer congested. The
router returns to the primary line exclusively.
Instructions: Enter the number of times the router should check if there is no longer a
congestion condition before bringing down the secondary line.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.104