Creating Line Pools
4-19
MCT1/MCE1 Clock Parameters
Use the following descriptions when you configure the clock parameters.
Parameter: Primary Clock
Default: Port 1 Ext Loop
Options: Internal | Port 1 Ext Loop | Port 2 Ext Loop | Auxiliary Ext
Function: Identifies the primary source of the transmit timing used by the single port
on the MCT1-1 Link Module and by both ports on the MCT1-2 Link
Module.
Internal – Generated by the clock chip on the Link Module
Port 1 Ext Loop – Generated by the signal coming in from Port 1
Port 2 Ext Loop – Generated by the signal coming in from Port 2
Auxiliary Ext – Generated from an external source using the DB9
interface
The internal and external clock source options include loop timing from
either port or an auxiliary timing source using the DB9 connector.
Instructions: Specify the source of the primary transmit clock.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.1.1.4