Configuring Dial Services
3-28
A forced dial and forced take down only occur when their values change from 2
to 1. To issue the
forced dial command, use the Technician Interface and change
the value to 1. The command syntax is
set wfSwservOptsEntry.wfSwservOptsForcedDial.<
circuit_no
.> 1;commit
To terminate a forced dial connection, you must issue a forced take down
command. To execute a
forced take down enter the following:
set wfSwservOptsEntry.wfSwservOptsForcedTakedown.<
circuit_no
.>
1;commit