Configuring IP Services
5-48
Figure 5-12. BGP AS Weights Window
BGP Weight Parameter Descriptions
This section describes how to set all parameters shown on the BGP Weight
Parameters and AS Weights windows.
Parameter: AS
Default: Null
Range: 1 to 65535
Function: Identifies the autonomous system to which you want to assign a weight.
Instructions: Enter the appropriate AS number.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.2.5.1.3.1.4