364 Appendix A: Network Examples
Enterprise Edge 2.0 Programming Operations Guide P0911588 Issue 01
Hardware: Enterprise Edge, an EE-DTM with one T1 DID line and three T1 E&M
lines.
Call Enterprise Edge and select lines to the public network
Gord is working from home, and needs to make a long-distance business call from
home. To avoid being charged, he dials the telephone number 555-4321 that maps
onto the Auto DN at work. After hearing the dial tone, Gord dials a line pool access
code 1234 to select a line to the public network. He then dials the long-distance
number.
Hardware: Enterprise Edge, EE-DTM with several T1 DID lines.
Heading Parameter Setting
Incoming trunk:
Trunk/Line Data Line 061 T1 DID
Access codes DISA DN 5321
Rec'd # length Rec'd # length 4 digits (can be from 2 to 7 digits,
but must match number of digits sent
by central office)
Outgoing trunk:
Trunk/Line Data Line 062
Line type
T1 E&M
Pool F
Access codes Line pool F 6 (up to 4 digits)
COS pswds Define restrictions. Define remote
access pkgs. Assign a restriction
filter to the line. Assign COS
passwords and filters for each Class
of Service.
Heading Parameter Setting
Incoming trunk:
Trunk/Line Data Line 061 T1 DID
Access codes Auto DN 4321
Rec'd # length Rec'd # length 4 digits (can be from 2 to 7 digits, but
must match number of digits sent by
central office)
Enterprise Edge
DID
Central Office
Central Office
business client
line pool
Kommentare zu diesen Handbüchern