Configuring WAN Line Services
7-38
117345-B Rev. 00
Before testing a port or logical line, you must set the test parameters:
Setting Port Test Parameters
Setting Logical Line Test Parameters
Then, start the tests:
Running Port Tests
Running Logical Line Tests
Setting Port Test Parameters
To set the port test parameters:
Site Manager Procedure
You do this System responds
1. In dynamic mode, click on a configured
MCT1 or MCE1 connector in the
Configuration Manager window.
The Logical Lines window opens
(Figure 7-9
on page 7-24).
2. Click on
Port Details.
The Port Parameters window opens.
3. Click on
Line Tests.
Note that the Line
Tests option appears only in dynamic
mode
.
The Port Actions window opens.
4. Edit the port action parameters, located in
the upper portion of the window.
5. After setting a parameter, click on
Apply
.
6. Click on
Done
when you are finished
setting port action parameters.
Note:
All changes you apply to the port in the Port Actions window are in
effect only while the window is active. When you exit the Port Actions
window, all port settings revert to the original settings.