Configuring WAN Line Services
9-14
117345-B Rev. 00
Before you can group lines, you must create the unused logical lines. To create the
unused logical lines:
Site Manager Procedure
You do this System responds
1. Start at the MCE1 or MCT1 Logical Lines
window. (See Chapter 7
for details.)
2. Click on an unconfigured MCE1 or MCT1
connector in the Configuration Manager
window.
The Port Application window opens.
3. Set the Port Application Mode parameter
to
NONPRI
,
then click on
OK
.
The Edit Clock Parameters window
opens.
4. Select a primary and secondary clock
source option, then click on
OK
.
The MCE1 or MCT1 Port Parameters
window opens
.
5. Set the port parameters, then click on
OK
. The MCE1 or MCT1 Logical Lines
window opens.
6. After customizing the port parameters,
click on
Add
.
The Add Circuit window opens.
Do not click on
OK
in the Add Circuit
window. Selecting OK adds a single-line
circuit for this logical line. You cannot
create a multiline circuit from a single-line
circuit.
7. Click on
Cancel
to create an unused
logical line.
The MCE1 or MCT1 Logical Lines
window reopens.
8. Repeat steps 7 and 8 for each unused
logical line you want to create.
The MCE1 or MCT1 Logical Lines
window now lists the unused logical lines.
Figure 9-7
shows four unused logical
lines.