Avaya Configuring WAN Line Services Bedienungsanleitung Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 294
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
Configuring Synchronous Services
117345-B Rev. 00
2-29
The lower the number, the higher the priority. For example, the router uses a line
of priority 1 before it uses a line of priority 2.
Set the priority for the interface.
Using Site Manager
See the Sync Priority parameter on page A-72 for information.
Setting the Hold Down Time
On a synchronous interface configured for dial services, you can specify a time
period (0 to 9999 seconds) for the router to wait before bringing down a backup
line. This delay allows time for the primary line to fully recover before
deactivating the backup line.
For a dial-on-demand interface, the Hold Down Time parameter is set to 3 seconds
by default.
For other interfaces, the Hold Down Time parameter is set to 0 by default. Set this
parameter to a value from 0 to 9999 seconds.
Using the BCC
hold-down-time
variable
For example:
sync/4/1# hold-down-time 0
Using Site Manager
See the Hold Down Time parameter on page A-69 for information.
Seitenansicht 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 293 294

Kommentare zu diesen Handbüchern

Keine Kommentare