Configuring MCE1 and MCT1 Services
117345-B Rev. 00
7-41
Setting the Signal Level (MCT1 Only)
By default, the T1 transmit power level is 0.0 dB. Specify a decibel level from
-15 dB to 1.5 dB, according to the length of the cable or as determined by the
carrier. See “Setting the Signal Level” earlier in this chapter for more information.
Enabling or Disabling the International Bit (MCE1 Only)
By default, MCE1 does not use the international bit in E1 frames. Enable or
disable use of the international bit for testing an MCE1 interface.
Running Port Tests
Port tests affect all logical lines associated with a port. To run MCE1 or MCT1
port tests:
Table 7-4
describes the BERT test commands you can send on any MCT1 or
MCE1 port. Table 7-5 describes the loopback commands you can send on an
MCT1 port only.
Site Manager Procedure
You do this System responds
1. Set the test parameters in the Port Actions
window. See “Setting Port Test
Parameters” earlier in this chapter.
2. Click on
Apply
.
3. To start a test, click on the appropriate
Send
command.
4. Repeat step 3
for each test you want to
run.
5. Click on
Done
. The MCE1 or MCT1 Port Parameters
window opens.