Configuring WAN Line Services
7-46
117345-B Rev. 00
Running Logical Line Tests
After setting test parameters, you can run the logical line tests.
To test a logical line on a DMCT1, QMCT1, or QMCT1 w/ DS0A port:
Note:
Although you can run tests on only one logical line per port, you can
run simultaneous logical line tests on other ports on the DMCT1 or QMCT1
module.
Site Manager Procedure
You do this System responds
1. Start at the QMCT1 or DMCT1 Logical
Line Actions window.
2. Select the logical line you want to test.
3. Click on the appropriate
Send
command.
Ta ble 7 -6
describes the BERT Send
commands for logical lines. Ta ble 7 -7
describes the fractional loopback Send
commands (for QMCT1 or QMCT1 w/
DS0A lines only).
Wait for the Logical Line Actions window
to update before selecting another Send
command.
4. Repeat step 3
for each test you want to
run.
5. Click on
Done
.
Table 7-6. Send Commands for Logical Line BERT Tests
Send Command Function
Insert 1 Error Inserts a single (nonrepeating) error into the bit stream
Insert 1 Error/1K Inserts a deliberate error into every thousandth position in the bit
stream
Insert 1 Error/1M Inserts a deliberate error into every millionth position
Disable Insert Error Stops the insertion of deliberate errors into the bit stream
Kommentare zu diesen Handbüchern