Seitenansicht 120
Configuring Line Services
5-26 114078 Rev. A
You can enable or disable extended addressing for the interface.
Enabling or Disabling Remote Loopback Detection
You can configure the router to automatically disable a synchronous interface
upon detecting its own BofL messages by enabling the Remote Loopback
Detection on an interface. If BofL is enabled, the device driver disables the
interface upon receiving its own BofL packets, assuming that the link has been put
into loopback mode. This function is disabled by default.
You can enable or disable remote loopback detection for the interface.
Setting the Sync Hold Down Time
On a synchronous interface configured for dial services, you can specify a time
period (0 to 9999 seconds) for the router to wait before bringing up the line. This
delay allows time for the primary line to recover before activating a dial-up line.
The Sync Hold Down Time parameter is set to 0 by default. You can set the hold
down time for the interface.
Setting Sync Priority
On a synchronous interface configured for dial or switched services, you can
assign a priority number (from 1 through 50) to each line within the same demand
or backup pool.
The lower the number, the higher the Sync Priority. For example, the router uses a
line of priority 1 before it uses a line of priority 2.
You can set the priority for the interface.
Site Manager: Extended Address parameter: page A-61
Site Manager: Remote Loopback Detection parameter: page A-69
Site Manager: Sync Hold Down Time parameter: page A-68
Site Manager: Sync Priority parameter: page A-70