Configuring Line Services
A-50 114078 Rev. A
Parameter: Signal Level (dB)
Path: MCT1 Connector > Edit Logical Lines > Port Details > MCT1 Port Parameters
Default: 0.0 dB
Options: -15 dB
| -7.5 dB | 0.0 dB | 0.5 dB | 0.8 dB | 1.1 dB | 1.5 dB
Function: Specifies the T1 transmit power level in decibels (dB).
The DS1 values of -15 and -7.5 dB are long-haul and the carrier determines
these values if 0.0 dB is not sufficient.
The DSX1 values of 0.0, 0.5, 0.8, 1.1, and 1.5 dB are short-haul and correlate
with cable length as follows:
• 0.0 dB -- 0 to 133 ft.
• 0.5 dB -- 133 to 255 ft.
• 0.8 dB -- 266 to 399 ft.
• 1.1 dB -- 399 to 533 ft.
• 1.5 dB -- 533 to 655 ft.
Instructions: Specify the decibel level according to the length of the cable or as the carrier
specifies.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.6
Parameter: Setup Alarm Threshold (seconds)
Path: MCT1 Connector > Edit Logical Lines > Port Details > MCT1 Port Parameters
Default: 2 seconds
Options: 2 to 10 seconds
Function: Specifies the time interval during which MCT1 tolerates a performance defect
or anomaly. If the performance defect or anomaly is still present when this time
interval expires, MCT1 records a performance failure and logs an event
message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.7