Site Manager Line Services Parameters
114078 Rev. A A-29
Parameter: BofL
Path: HSSI Connector > Edit Line > Edit HSSI Parameters
Default: Enable
Options: Enable
| Disable
Function: Enables the transmission of proprietary Ethernet-encapsulated Bof L messages
over a point-to-point connection between the local router and a remote peer.
Instructions: Set to Enable or Disable, depending on whether you want to transmit BofL
messages over this HSSI interface. If you enable BofL locally, you must also
configure the remote peer to enable BofL.
We recommend that you enable BofL for point-to-point connections between
Bay Networks peers. If, however, such a connection occurs through a wide area
transport service such as Frame Relay or SMDS, you must disable BofL.
MIB Object ID: 1.3.6.1.4.1.18.3.4.7.1.7
Parameter: BofL Frequency
Path: HSSI Connector > Edit Line > Edit HSSI Parameters
Default: 1 second
Options: 0 to 60 seconds
Function: Specifies the interval in seconds between BofL transmissions. This parameter is
valid only if BofL is set to Enable.
After sending a BofL message, the router starts a timer that has a value equal to
5 times the setting of this parameter. If the router does not receive a BofL
message from the remote peer before the timer expires, the router disables the
HSSI circuit, and then attempts to restart it.
Instructions: Accept the default, 1 second, or specify a new value, making certain that both
ends of the point-to-point connection are configured with the same value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.7.1.8
Kommentare zu diesen Handbüchern