Avaya Configuring Line Services Bedienungsanleitung Seite 127

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 301
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 126
Configuring Line Services
6-2 114078 Rev. A
To select the port application using Site Manager:
1. Click on an unconfigured MCE1 or MCT1 connector in the
Configuration Manager window.
The Port Application window appears (
Figure 6-1.).
Figure 6-1. Port Application Window
2. Set the Port Application Mode parameter to NONPRI or PRI.
Select NONPRI to indicate that all the lines have a permanent circuit number
and are for leased lines, Frame Relay, or permanent connections for other
non-ISDN PRI applications.
Select PRI to indicate that the lines are for switched circuits using ISDN.
3. Click on OK.
The Edit Clock Parameters parameters window appears. Go to “Setting the
Clock Parameters.
Site Manager: Port Application Mode parameter: page A-43 (MCE1)
Site Manager: Port Application Mode parameter: page A-47 (MCT1)
Note: You must configure non-PRI applications with MCE1-I modules. When
you configure the MCE1-I module, Site Manager displays a warning to
indicate that this version of MCE1 does not support ISDN.
Seitenansicht 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 300 301

Kommentare zu diesen Handbüchern

Keine Kommentare