Resolving Problems 10-3
Troubleshooting
Chapter 10
(continued)
DEFINITY system
connection test does not
pass. Cannot connect to
DEFINITY system.
No administration session
available.
Request an administration
session from the DEFINITY
system administrator.
Phone number is incorrect;
password and/or user ID are
incorrect.
Obtain the correct phone
number; obtain the correct user
ID and password from the
DEFINITY system
administrator.
User ID permissions are not
correct.
Obtain the correct user ID
permission from the
DEFINITY system
administrator.
Data Module is being used
to connect to the switch and
BCMS Vu is not
communicating with the
data module.
Check communication
between PC and data module
using a terminal emulator such
as HyperTerminal™. Refer to
“Using a Terminal Emulator”
on page 10-39.
The serial port specified to
connect to the data module
is connected to something
else or is not connected.
Specify correct serial port in
Server Configuration Wizard.
Server is intentionally not
connected to DEFINITY
system.
Start BCMS Vu Simulator to
run BCMS Vu Server and
Client with randomly
generated data.
(continued)
DEFINITY system
connection test does not
pass. Cannot connect to
DEFINITY system.
TCP/IP is being used to
connect to the switch and
the IP address or hostname
and/or port are invalid
Obtain the correct IP address
or host name.
Starting/Connecting Problems
Problem Probable Cause Action