Avaya R2 Betriebsanweisung Seite 224

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 268
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 223
10-24 Resolving Problems
Troubleshooting
Wallboard Problems
Problem Probable Cause Action
Reports and messages do
not appear on Wallboard.
Wallboard is not con-
nected to the specified
port on the specified
PC.
Wallboard software is
not running on the PC
to which the wallboard
is attached.
Wallboard is not prop-
erly registered.
Wallboard address is
not correct.
Wallboard has a poor
physical connection.
Correct problem.
Refer to “Installing a
Wallboard” in BCMS Vu
Software R2 V2 Installation
Guide,, and “Registering
Wallboards” on page 4-12.
Wallboard COM Port is not
activated in your PC
hardware configuration.
Consult your PC user guide or
its manufacturer’s technical
support to see how to tell if
your COM Port has been
disabled.
Wallboard is not changing.
Data on wallboard
indicates zero value and
doesn’t update for a long
period of time.
Server lost connection to the
DEFINITY system.
Check connection on status
bar. If the connection is not
active and if the DEFINITY
system is still operational, try
to reconnect to the DEFINITY
system
Make sure wallboard software
is running on the PC to which
the wallboard is connected.
Seitenansicht 223
1 2 ... 219 220 221 222 223 224 225 226 227 228 229 ... 267 268

Kommentare zu diesen Handbüchern

Keine Kommentare