Customizing PPP
117360-A Rev. A 3-37
Using Site Manager
To configure link quality monitoring on this PPP interface, do the tasks in the
following table.
Specifying the Asynchronous Modem Control Character Map
During LCP negotiations, the peers negotiate the characters that they will
recognize as asynchronous modem control characters. PPP creates a 32-bit map
that represents the negotiated control characters. Both routers use this map in
sending and receiving data packets. While the default value serves for almost all
modems, you can configure the map for other modem control characters if
necessary.
Site Manager Procedure
You do this System responds
1. From the Protocols menu, choose PPP. The Interfaces menu appears.
2. Choose Interfaces. The Interfaces window opens.
3. Set Link Quality Protocol.
(See page A-21.)
4. Set Peer Link Quality Report Timer.
(See page A-22.)
5. Set LQR Reporting Period.
(See page A-22.)
6. Set Inbound Link Quality.
(See page A-23.)
7. Set Outbound Link Quality.
(See page A-23.)
8. If you have no other Interface parameters
to configure, click on OK. Otherwise,
continue with the Interface configuration.
The Configuration Manager window
opens.
Kommentare zu diesen Handbüchern