304 Chapter 32 Private networking: MCDN over PRI and VoIP
NN40020-603NN40020-603
UDP-specific programming
BCM UDP programming
Private Dialing Plan: Type=UDP, HomeLoc=<three-digit prefix>
Private Access Code <unique code>
Private DN length <total of Private Access Code + Location Code + DN length>
Example: if dialing string is 6 393 2222, then set private DN to 8
Program the DestCodes for
the other nodes
AccessCode plus the ESN, absorb the AccessCode.
Example: For AccessCode=6; DestCode=6393[Absorb=1]
M1 UDP programming
Private Access Code Overlay 86, LD 86
REQ: PRT
CUST: 0
FEAT: ESN
To change Private Access
Code:
Overlay 86, LD 86
REQ: CHG
CUST: 0
FEAT: ESN, keep pressing
until you reach the AC1 prompt
At the AC1 prompt, make your
choice
Check UDP programming Overlay 90, LD 90
REQ: PRT
CUST: 0
FEAT: NET
TYPE: LOC
LOC: press enter, all the programmed location codes are listed
HLOC is the home location of the M1
Program UDP values to
route
Overlay 90, LD 90
REQ: CHG
CUST: 0
FEAT: NET
TYPE: AC1
LOC: (enter a number)
RLI: (enter the RLI corresponding to the route)